Annicom Axio Logo  
    +44(0)1420487788  
 
home | about us | products | datasheets | account
 
   
datasheetdetails
 <<  |  <  |   AX-UL-SPx - Ultrasonic Level Sensor- Liquid Content (Fixed Ranges)
AX-UL-SPA-5A0-4 / Ultrasonic Level Transmitter (Clean & Waster Water), 4-20mA/HART O/P, 0.15-3 Meters, PP Housing, 1" BSP Thread POA Qty
AX-UL-SPA-590-4 / Ultrasonic Level Transmitter (Clean & Waster Water), 4-20mA/HART O/P, 0.18-5 Meters, PP Housing, 1½" BSP Thread POA Qty
AX-UL-SPA-580-4 / Ultrasonic Level Transmitter (Clean & Waster Water), 4-20mA/HART O/P, 0.2-8 Meters, PP Housing, 2" BSP Thread POA Qty
AX-UL-SPA-570-4 / Ultrasonic Level Transmitter (Clean & Waster Water), 4-20mA/HART O/P, 0.25-10 Meters, PP Housing, 2" BSP Thread POA Qty
AX-UL-SPA-560-4 / Ultrasonic Level Transmitter (Clean & Waster Water), 4-20mA/HART O/P, 0.25-12 Meters, PP Housing, 2" BSP Thread POA Qty
AX-UL-SPA-540-4 / Ultrasonic Level Transmitter (Clean & Waster Water), 4-20mA/HART O/P, 0.35-18 Meters, PP Housing, 2" BSP Thread POA Qty
AX-UL-SPA-390-4 / Ultrasonic Level Transmitter (Clean & Waster Water), 4-20mA+HART O/P, 0.2-4 Meters, PP Housing, 1",1½" BSP Thread POA Qty
AX-UL-SPA-380-4 / Ultrasonic Level Transmitter (Clean & Waster Water), 4-20mA+HART O/P, 0.25-6 Meters, PP Housing, 2" BSP Thread POA Qty
AX-UL-SPA-370-4 / Ultrasonic Level Transmitter (Clean & Waster Water), 4-20mA+HART O/P, 0.35-8 Meters, PP Housing, 2" BSP Thread POA Qty
AX-UL-SPA-360-4 / Ultrasonic Level Transmitter (Clean & Waster Water), 4-20mA+HART O/P, 0.35-10 Meters, PP Housing, 2" BSP Thread POA Qty
AX-UL-SPA-340-4 / Ultrasonic Level Transmitter (Clean & Waster Water), 4-20mA+HART O/P, 0.45-15 Meters, PP Housing, 2" BSP Thread POA Qty
AX-UL-SPA-320-4 / Ultrasonic Level Transmitter (Clean & Waster Water), 4-20mA+HART O/P, 0.6-25 Meters, PP Housing, 2" BSP Thread POA Qty
 <<  |  <  | OVERVIEW | SPECIFICATION | DATASHEETS        

The AX-UL-SP is a robust non display fixed range of IP68-rated ultrasonic level transmitters for tanks and sumps, offering non-intrusive measurement with a standard 4–20mA output. These non display ultrasonic level transmitters are available in 3m, 4m, 5m, 6m, 8m, 10m, 12m, 15m. 18m & 25m ranges, with optional Relay and HART output. AX-UL-SP is designed to monitor liquid level in sumps or tanks, for tank contents measurement, or open channel flow measurement. Separate models are available for water and diesel
Product Features
• Non-contact level measurement
• 2-wire integrated level transmitters
• Maximum 25 m (82 ft) measuring range
• Level measurement in basins, wells, sumps, lift-stations
• Full temperature compensation
• Wide application area from wastewater to aggressive chemicals
• For most liquids, including flammable liquids
• Suitable for level measurement of hydrocarbons, acids, aggressive liquids, any water based medium

Measuring Range
From 0.15 Meter up to 3/4/5/6/8/10/12/15/18 & 25 Meters
System
2 Wire
Accuracy
AX-UL-SPx-5 ± (0.1% of measured distance +0.025% of Range) ± (0.05% of range)
AX-UL-SPx-3 ± (0.2% of measured distance +0.05% of range)

Output
Analogue (4-20mA) + SPDT, 30V DC, 1A DC, HART® 7
Ambient Temperature
-30°C to +80°C (-22°F to +176°F)
Process Temperature
AX-UL-SPx-5 PP, PVDF transducers
AX-UL-SPx-3 With PP transducer
-20°C to +70°C (-4°F to + 158°F)
With PVDF transducer
-20°C to +80°C (-4°F to + 176°F)
Power Supply
AX-UL-SPx-5 11–36V DC
AX-UL-SPx-3 12–36V DC/ 48–720 mW

Housing
AX-UL-SPx-5 PP or PVDF
AX-UL-SPx-3 PP or PVDF (Teflon PTFE has PP housing)

Electrical Connection
4x 0.5 mm² (AWG20) (relay version
Standard cable length
5 m (16.5 ft)
(can be ordered up to 30 m [100 ft])

Ingress Protection
IP68
Weight
AX-UL-SPx-5 0.8 – 1.2 Kg (1.8 – 2.65 lb)
AX-UL-SPx-3 1.2 – 2 Kg (2.65 – 4.4 lb)

Country Of Origin
Hungary

AX-UL-SPx.pdf / Ultrasonic Level Transmitter- Liquid Content (Fixed Ranges)