datasheetdetails
|
<< | < | AX-GS-TC3-H2 - Hydrogen sensor - Wall Mount
|
|
The AX-GS-TC3 units are a range of Gas Detectors providing accurate measurements of specific gases. The H2 units respond to hydrogen gas and have 4-20mA and/or addressable outputs. The units are supplied pre-calibrated and ready for use. The Catalytic pellistor unit is a cost effective version that will respond to all flammable gases, and is calibrated for Hydrogen LEL. This unit has 3-wire 4-20mA and addressable outputs. The Electrochemical units respond to Hydrogen specifically and are calibrated for 0-1000ppm. These units are either 2-wire, 4-20mA loop powered output or addressable output. |
Product Features
| • Detector technology to suit application • Industry Standard 4-20mA Output
| • Pre-calibrated • Compensated for temperature and drift
|
Power
| 18-28Vdc
| Output
| 4-20mA Linear Output into 500O load max (24Vdc supply)
| Addressable Output
| 4-wire (for use with Addressable Controller - see unit type)
| General Accuracy
| ±2% of Range
| Temperature range
| -5 to 55°C
| Humidity range
| 5-95% RH non-condensing
| Housing
| ABS enclosure IP54
| Weight
| 425g
|
AX-GS-TC3-H2.pdf / Hydrogen sensor - Wall Mount | |
|
|
|